Model |
PA-900B (Advanced Model) |
Display |
10.4 inch high visibility color TFT display |
Ventilation Mode |
A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, VCV, SPONT MANUAL |
Minute Volume |
Greater than or equal to 18L |
Back-up Power Supply |
At least 4 hours |
Tidal Volume |
Adjustable range: 20-1500ml, Display range: 0-2000ml |
Respiratory Rate |
1-99bpm |
Inspiratory/expiratory (I:E) ratio |
4:1-1:4 |
PEEP |
0-10cmH2O |
SIMV Rate |
1-20bpm |
Inspiratory Pressure Trigger |
-10-10cmH2O |
Trigger Sensitivity (flow) |
1-10L/m |
Inspiratory Plateau |
Adjustable from 0-50% of inspiratory time |
Adjustable Oxygen Concentration |
21-100% |
Gas Supply Requirement |
280~600 kPa medical grade oxygen and compressed air supply |
Pressure Limit |
1.0kPa~6.0kPa |
Maximum Safe Operating Pressure |
≤6.0kPa |
Tidal Volume Alarm |
Upper Limit: 10~2000ml, Lower Limit: 0~1800ml |
Airway Pressure Alarm |
Upper Limit: 0.1~6kPa, Lower Limit: 0~5kPa |
Oxygen Concentration Alarm |
Upper Limit: 22~100%, Lower Limit: 21~80% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Common Features
Operating Modes: Pneumatically driven & Nonhazardous environmentally friendly
electronically controlled, closed, semi-closed frame, precise construction, elegant design,
and semi-open equipped with automated self-checking
Pneumatically driven electrically controlled function during startup and an automatic
ventilator, can be used for emergency clinical self-calibrating sensor
resuscitation and respiratory therapy Alarms: Audible and/or visual alarms for
Display: Built-in10.4 inch color TFT fully ventilation volume, tidal volume, oxygen
adjustable display, able-display Pressure-Time, concentration, asphyxia, airway pressure,
Frequency-Time, Pressure-Volume, intubation disconnection, low oxygen, power
Frequency-Volume and any two waveforms failure and other alarms, also features a alarm
simultaneously on screen history query function
Trigger Types: Pressure trigger, Flow trigger Advanced Model Exclusive Features
Sigh: Ability to insert 1-8 sigh breaths in
every 100 breaths, ventilation should be no Equipped with professional medical grade air
less than 1.5 the tidal volume compressor tailored for long clinical times and
Features built-in dual electronic flow sensors low noise requirements
and dual respiratory modules Air Compressor
Power Failure Support Functions:
Automatically converts-standby mode during Air Compressor:220VAC±10%,50±1Hz,
AC power outages 700VA, also features good protective
Monitor Parameters: tidal volume, respiration grounding against electrical activity
rate, airway pressure, I:E ratio, inspiratory & Output Gas Pressure:0.4MPa±20%
expiratory status, inspiratory trigger and others Continuous output gas flow greater than or
Equipped with infrared turbine flow sensor; equal to 20L/min
precisely measures gas flows, stable and Instantaneous output gas flow great than
reliable equal to 60L/min
9 Level adjustable humidifier
Bulit-in 10.4'LCD display, P-T,F-T,P-V,F-V waveforms, with lock screen,Screen could be rotated freely.Ventilation Modes: A/C,SIPPV,IPPV,SIMV,PSIMV,PSV,CPAP,PCV,VCV,SPONT,MANNUAL
Tidal Volume: Adjustable:50~1500ml , Display: 0~2000ml
Oxygen Concentration: 21%~100%
Pressure trigger, flow trigger,Pressure trigger:1.0 ~ 10.0 L/min
Inspiratory Plateau time:0-50% adjustable
Double built-in electronical flow sensors and Respiratory modular